Check the package
KIT0139 probe + SEN0262 current-to-voltage converter; probe supply and converter supply are separate.
Confirm delivery →TECHNICAL REFERENCE / PROJECT ENQUIRY
Hydrostatic liquid level · 0-5 m

Material reference: RS-LVL-001-01. Brand: ROGERSENSE. Hardware and document revision are confirmed for each project.
Define the sensing task, interface and installation requirements with our engineering team.
Model-specific values and conditions. Unconfirmed values are marked TBD.
| Parameter | Published value / condition | Ref. |
|---|---|---|
| Measurement | Hydrostatic liquid level · Conversion from pressure to depth depends on liquid density | L1 |
| Nominal range | 0-5 m · Confirm calibration medium / density before publication | L1 |
| Accuracy | 0.5% as published · Reference basis and test conditions not stated; do not invent +/-0.5% FS | L2 |
| Probe output | 4-20 mA · Analog current loop; no native RS485 | L2 |
| Probe supply | 12-36 V DC · Not the converter board supply | L2 |
| Converter supply | 3.3-5.5 V · SEN0262 board only; separate from 12-36 V probe | L2 |
| Operating temperature | -20 to +70 deg C | L2 |
| Diaphragm / housing | 316L / 304 stainless steel | L2 |
| Cable / protection | 5 m / IP68 as published · Terminal / converter board are not established as submersible | L2 |
| Included items | Level probe x1; SEN0262 converter x1 · Kit SKU; do not omit converter in the sale description | L1 |
| Probe overload / life reference | 300% as listed; 1e8 cycles at 25 deg C; test basis TBD | L2 |
| Air-vent tube | Thick red tube is a pressure vent, not an electrical conductor | L2 |
| Signal / item | Source reference | Ref. |
|---|---|---|
| Probe red / black | VCC positive / negative return, per source labels · Follow the current-loop connection drawing, not a TTL wiring assumption | L2 |
| Thick red tube | Air-guiding tube, not an electrical terminal · Keep reference vent dry | L2 |
| Converter terminals | GND, VCC, Signal, I+, I- · Consult source connection drawing | L2 |
Units: mm. Source dimensions only; unavailable details are TBD.
| Item | Published value / condition | Ref. |
|---|---|---|
| Probe body diameter / length | 28 / 108 mm | L2 |
| Tail feature / cable length | 50 / 5000 mm | L2 |
| Diaphragm / housing | 316L / 304 stainless steel | L2 |
| Probe protection | IP68 as published; converter protection TBD | L2 |
| Datum / tolerances / installation depth limit | TBD / TBD / TBD | L2 |
| Capability | How it is provided |
|---|---|
| Device interface | Refer to model-specific documentation |
| MQTT | Acquisition and gateway integration available; model-specific scope to agree |
| OTA | Firmware and update lifecycle services available; compatible device scope to agree |
KIT0139 probe + SEN0262 current-to-voltage converter; probe supply and converter supply are separate.
Confirm delivery →Specifications, dimensions, interface notes and available SDKs.
View documents →Submersible Liquid Level Kit
No reviews yet.