Check the package
Configuration and delivery contents are confirmed in the integration project; no online sample offer.
Confirm delivery →TECHNICAL REFERENCE / PROJECT ENQUIRY
PM1.0, PM2.5, PM10 / 0-1000 ug/m3 · +/-15 ug/m3 at 0-100; +/-15% of reading at 101-1000 ug/m3

Material reference: RS-PMD-001-01. Brand: ROGERSENSE. Hardware and document revision are confirmed for each project.
Define the sensing task, interface and installation requirements with our engineering team.
Model-specific values and conditions. Unconfirmed values are marked TBD.
| Parameter | Published value / condition | Ref. |
|---|---|---|
| Targets / range | PM1.0, PM2.5, PM10 / 0-1000 ug/m3 · pp.3-5; laser-scattering module | E3 |
| PM2.5 accuracy | +/-15 ug/m3 at 0-100; +/-15% of reading at 101-1000 ug/m3 · p.3; 25+/-2 deg C, 50+/-10% RH, TSI8530 reference, cigarette aerosol, GBT18801-2015 | E3 |
| Supply / active current | 4.9-5.5 V DC / <120 mA · p.3 | E3 |
| Outputs | UART TTL 3.3 V and PWM 3.3 V · p.3 | E3 |
| UART | 9600 bit/s; 8-N-1 · p.4 | E3 |
| Detection interval / response | 1 s / T90 <45 s · p.3; different metrics | E3 |
| Operating environment | -10 to +50 deg C; 0-80% RH, non-condensing · p.3 | E3 |
| Dimensions | 50 x 32.4 x 21 mm · p.3 | E3 |
| Particle size / warm-up | 0.3-10 um / 30 s | E3 |
| Dormancy current | <20 mA | E3 |
| Storage / mass | -30 to +70 deg C / <38 g | E3 |
| PM2.5 accuracy conditions | 25 +/-2 deg C, 50 +/-10% RH; TSI8530 cigarette aerosol, GB/T18801 reference | E3 |
| Signal / item | Source reference | Ref. |
|---|---|---|
| 1 / 2 | VDD +5 V / GND · p.4 | E3 |
| 4 / 5 | RXD / TXD, TTL 3.3 V · p.4 | E3 |
| 8 | PWM output, TTL 3.3 V · p.4; remaining pins per original drawing | E3 |
Units: mm. Source dimensions only; unavailable details are TBD.
| Item | Published value / condition | Ref. |
|---|---|---|
| Length x width x height | 50 x 32.4 x 21 mm | E3 |
| Mass | <38 g | E3 |
| Inlet / outlet clearances | TBD; keep both unobstructed | E3 |
| Mounting holes / datum / tolerances | TBD / TBD / TBD | E3 |
| Capability | How it is provided |
|---|---|
| Device interface | Refer to model-specific documentation |
| MQTT | Acquisition and gateway integration available; model-specific scope to agree |
| OTA | Firmware and update lifecycle services available; compatible device scope to agree |